Cells for Absorption Measurement, UV-range
PART NO.4AJ-9144751
79556||82191||79529||82402||79162||81656||79593||81119||79316||81643||79397||81597||81112||79370||81201||79470||79701||82401||79750||81657
Power supply||Range m||Path length mm||Detection limit||Int. width mm||Antistatic||Max. capacity µl||Type||Grain size||Angle side necks||Cap size||Ext. width mm||Min. permitted ambient temperature °C||Ext. height mm||mV range accuracy||Olives ext. Ø||Wavelength||Spectral bandwidth||Flow rate||PK
||200...2500||10|| ||2|| ||700||700 µl||Lid||PTFE|| ||12.5||12.5||45||12.5 x 12.5 x 45 mm|| ||Micro|| || ||1
Hellma
104-002-10-40
VG195514162
9144751
634-9080
Cuvettes UV-range
Cuvettes for absorption measurement
Cells/Optical cells UV-range
Cells/Optical cells for absorption measurement
Absorption cells
Cells/Optical cells glass
3
1
11
1
Price: £140.40
Low Stock
PART NO.4AJ-9144730
79556||82191||79529||82402||79162||81656||79593||81119||79316||81643||79397||81597||81112||79370||81201||79470||79701||82401||79750||81657
Power supply||Range m||Path length mm||Detection limit||Int. width mm||Antistatic||Max. capacity µl||Type||Grain size||Angle side necks||Cap size||Ext. width mm||Min. permitted ambient temperature °C||Ext. height mm||mV range accuracy||Olives ext. Ø||Wavelength||Spectral bandwidth||Flow rate||PK
||200...2500||10|| ||4|| ||1400||1,400 µl||Stopper||PTFE|| ||12.5||12.5||46||12.5 x 12.5 x 46 mm|| ||Semi-Micro|| || ||1
Hellma
114-10-40
VG195514122
9144730
634-9158
Cuvettes UV-range
Cuvettes for absorption measurement
Cells/Optical cells UV-range
Cells/Optical cells for absorption measurement
Absorption cells
Cells/Optical cells glass
0
1
7
1
Price: £185.40
Out of Stock
PART NO.4AJ-9144465
79556||82191||79529||82402||79162||81656||79593||81119||79316||81643||79397||81597||81112||79370||81201||79470||79701||82401||79750||81657
Power supply||Range m||Path length mm||Detection limit||Int. width mm||Antistatic||Max. capacity µl||Type||Grain size||Angle side necks||Cap size||Ext. width mm||Min. permitted ambient temperature °C||Ext. height mm||mV range accuracy||Olives ext. Ø||Wavelength||Spectral bandwidth||Flow rate||PK
||200...2500||50|| ||4|| ||7000||7,000 µl||Lid||PTFE|| ||12.5||52.5||45||12.5 x 52.5 x 45 mm|| ||Semi-Micro|| || ||1
Hellma
104-50-40
VG195513502
634-9125
Cuvettes UV-range
Cuvettes for absorption measurement
Cells/Optical cells UV-range
Cells/Optical cells for absorption measurement
Absorption cells
Cells/Optical cells glass
0
1
3
1
Price: £262.80
Out of Stock
PART NO.4AJ-9144460
79556||82191||79529||82402||79162||81656||79593||81119||79316||81643||79397||81597||81112||79370||81201||79470||79701||82401||79750||81657
Power supply||Range m||Path length mm||Detection limit||Int. width mm||Antistatic||Max. capacity µl||Type||Grain size||Angle side necks||Cap size||Ext. width mm||Min. permitted ambient temperature °C||Ext. height mm||mV range accuracy||Olives ext. Ø||Wavelength||Spectral bandwidth||Flow rate||PK
||200...2500||10|| ||4|| ||1400||1,400 µl||Lid||PTFE|| ||12.5||12.5||45||12.5 x 12.5 x 45 mm|| ||Semi-Micro|| || ||1
Hellma
104-10-40
VG195513102
9144460
634-9122
Cuvettes UV-range
Cuvettes for absorption measurement
Cells/Optical cells UV-range
Cells/Optical cells for absorption measurement
Absorption cells
Cells/Optical cells glass
7
1
2
1
Price: £123.30
Low Stock
PART NO.4AJ-6250017
79556||82191||79529||82402||79162||81656||79593||81119||79316||81643||79397||81597||81112||79370||81201||79470||79701||82401||79750||81657
Power supply||Range m||Path length mm||Detection limit||Int. width mm||Antistatic||Max. capacity µl||Type||Grain size||Angle side necks||Cap size||Ext. width mm||Min. permitted ambient temperature °C||Ext. height mm||mV range accuracy||Olives ext. Ø||Wavelength||Spectral bandwidth||Flow rate||PK
||200...2500||10|| ||4|| ||1000||1,000 µl||Lid||PTFE|| ||12.5||12.5||45||12.5 x 12.5 x 45 mm|| ||Semi-Micro|| || ||1
Hellma
108-000-10-40
634-9154
Cuvettes UV-range
Cuvettes for absorption measurement
Cells/Optical cells UV-range
Cells/Optical cells for absorption measurement
Absorption cells
Cells/Optical cells glass
2
1
5
1
Price: £163.80
Low Stock
PART NO.4AJ-6084722
79556||82191||79529||82402||79162||81656||79593||81119||79316||81643||79397||81597||81112||79370||81201||79470||79701||82401||79750||81657
Power supply||Range m||Path length mm||Detection limit||Int. width mm||Antistatic||Max. capacity µl||Type||Grain size||Angle side necks||Cap size||Ext. width mm||Min. permitted ambient temperature °C||Ext. height mm||mV range accuracy||Olives ext. Ø||Wavelength||Spectral bandwidth||Flow rate||PK
||200...2500||10|| ||2|| ||500||500 µl||Lid||PTFE|| ||12.5||12.5||45||12.5 x 12.5 x 45 mm|| ||Micro|| || ||1
Hellma
108-002-10-40
634-9240
Cuvettes UV-range
Cuvettes for absorption measurement
Cells/Optical cells UV-range
Cells/Optical cells for absorption measurement
Absorption cells
Cells/Optical cells glass
0
1
13
1
Price: £175.50
Out of Stock
PART NO.4AJ-9144758
79556||82191||79529||82402||79162||81656||79593||81119||79316||81643||79397||81597||81112||79370||81201||79470||79701||82401||79750||81657
Power supply||Range m||Path length mm||Detection limit||Int. width mm||Antistatic||Max. capacity µl||Type||Grain size||Angle side necks||Cap size||Ext. width mm||Min. permitted ambient temperature °C||Ext. height mm||mV range accuracy||Olives ext. Ø||Wavelength||Spectral bandwidth||Flow rate||PK
||200...2500||10|| ||2|| ||400||400 µl||Lid||PTFE|| ||12.5||12.5||40||12.5 x 12.5 x 40 mm|| ||Micro|| || ||1
Hellma
115-10-40
VG195514192
9144758
634-9242
Cuvettes UV-range
Cuvettes for absorption measurement
Cells/Optical cells UV-range
Cells/Optical cells for absorption measurement
Absorption cells
Cells/Optical cells glass
3
1
15
1
Price: £181.80
Low Stock