Digital optical oxygen sensor with intergrated temperture sensor
Design according to the minimum requirements defined by ATV (waste water association) in bulletin M256 for meters to be used at waste water treatment plants
Calibration free optical oxygen sensor (Flureszenzprinziple)
- To be connected to the IQ SENSOR NET multiparameter measuring system
* With integrated temperature sensor
Equipped with the following performance features:
- Factory calibration (IQMC-Method)
- Highest stability (EPRS-Referencemethod)
- Long lifetime (greelight-Technology)
- No flow is needed
- Integrated lightning protection
- Insensitive for H2S, chlorine, ionogenic substances
- Changable sensor cap with stored calibration data
- Automatical temperature compensation
- Digital data transfer
- With screw/plug connector for connection of the SACIQ sensor connection cable
Measuring range (25°C):
- 0 ... 20 mg O2/l
- 0 ... 200 % air saturation
Measurement accuracy:
- +/- 0.05 mg/l, O2 < 1mg/l
- +/- 0.1 mg/l, O2 > 1mg/l
Reproducibility:
- 0.05 mg/l
Temperature range:
- Measurement range: -5°C ... 50°C
- Storage range: -25°C ... 60°C
Pressure resistance:
- max. 10 bar
Sensor length:
- 428 x 40mm (incl. adapter of the sensor connection cable)
Material:
- Membrane-/sensor cap, protective hood: POM, PVC, Silicon
- Enclosure shaft: V4A stainless steel 1.4571
Type of protection:
- IP 68 (with connected SACIQ sensor connection cable)
Power consumption:
- 0.75 Watt
Sensorcap for FDO
Sensorcap for FDO® 700 IQ and FDO® 700 IQ-SW usable for freshwater and seawater
- Integrated date chip for storage of calibration date
- Manufacturer calibrated
Potentiostatic D.O. sensor with integrated temperature sensor
Design according to the minimum requirements defined by ATV (Waste water association) in bulletin M 256 for meters to be used at waste water treatment plants
Potentiostatic D.O. sensor (3-electrode principle)
- To be connected to the EcoLine® or QuadroLine® series measuring transmitters
* With integrated temperature sensor and built-in preamplifier for low impedance, interference-free signal transmission
Equipped with the following features:
- Integrated lightning protection
- Sensor monitoring function (SensCheck)
- Zero current free electrode system
- Exchangeable membrane head with robust 50 um special membrane
- Lowest incident flow required
- Double thermistor system for temperature compensation
- OxiCal air calibration without accessories
Measuring range (25°C):
- 0 ... 60mg O2/l
- 0 ... 600 % saturation
Response time (t90):
- 180 seconds
Sensor length:
- 196mm
Connection cable:
- 7m long, with watertight plug (IP 65)
Type of protection:
- IP 68 (sensor)
Potentiostatic D.O. sensor with integrated temperature sensor
Design according to the minimum requirements defined by ATV (Waste water association) in bulletin M 256 for meters to be used at waste water treatment plants
Potentiostatic D.O. sensor (3-electrode principle)
- To be connected to the EcoLine® or QuadroLine® series measuring transmitters
* With integrated temperature sensor and built-in preamplifier for low impedance, interference-free signal transmission
Equipped with the following features:
- Integrated lightning protection
- Sensor monitoring function (SensCheck)
- Zero current free electrode system
- Exchangeable membrane head with robust 50 um special membrane
- Lowest incident flow required
- Double thermistor system for temperature compensation
- OxiCal air calibration without accessories
Measuring range (25°C):
- 0 ... 60mg O2/l
- 0 ... 600 % saturation
Response time (t90):
- 180 seconds
Sensor length:
- 196mm
Connection cable:
- 15m long, with watertight plug (IP 65)
Type of protection:
- IP 68 (sensor)
Potentiostatic D.O. sensor with integrated temperature sensor
Design according to the minimum requirements for measuring instruments used at waste water treatment plants defined by ATV (waste water association) in bulletin M256
Potentiostatic D.O. sensor (3-electrode principle)
- To be connected to the EcoLine® or QuadroLine® series measuring transmitters
* Especially suitable for use in denitrification and for oxygen addition measurements
* With integrated temperature sensor and built-in preamplifier for low impedance, interference-free signal transmission
Equipped with the following features:
- Integrated lightning protection
- Sensor monitoring function (SensCheck)
- Zero current free electrode system
- Exchangeable membrane head with robust 25um special membrane
- Extremely short response time
- Low incident flow required
- Double thermistor system for temperature compensation
- OxiCal air calibration without accessories
Measuring range (25°C):
- 0 ... 60mg O2/l
- 0 ... 600 % saturation
Response time (t90):
- 30 seconds
Sensor length:
- 196mm
Connection cable:
- 7m, with watertight plug (IP 65)
Type of protection:
- IP 68 (sensor)
Potentiostatic D.O. sensor with integrated temperature sensor
Design according to the minimum requirements for measuring instruments used at waste water treatment plants defined by ATV (waste water association) in bulletin M256
Potentiostatic D.O. sensor (3-electrode principle)
- To be connected to the EcoLine® or QuadroLine® series measuring transmitters
* With integrated temperature sensor and built-in preamplifier for low impedance, interference-free signal transmission
Equipped with the following features:
- Integrated lightning protection
- Zero current free electrode system
- Exchangeable membrane head with robust 50um special membrane
- Lowest incident flow required
- Double thermistor system for temperature compensation
- OxiCal air calibration without accessories
Measuring range (25°C):
- 0 ... 60 mg O2/l
- 0 ... 600 % saturation
Response time (t90):
- 180 seconds
Sensor length:
- 196mm
Connection cable:
- 7m long, with watertight plug (IP65)
Type of protection:
- IP 68 (sensor)
Potentiostatic D.O. sensor with integrated temperature sensor
Design according to the minimum requirements for measuring instruments used at waste water treatment plants defined by ATV (waste water association) in bulletin M256
Potentiostatic D.O. sensor (3-electrode principle)
- To be connected to the EcoLine® or QuadroLine series measuring transmitters
* With integrated temperature sensor and built-in preamplifier for low impedance, interference-free signal transmission
Equipped with the following features:
- Integrated lightning protection
- Zero current free electrode system
- Exchangeable membrane head with robust 50um special membrane
- Lowest incident flow required
- Double thermistor system for temperature compensation
- OxiCal air calibration without accessories
Measuring range (25°C):
- 0 ... 60mg O2/l
- 0 ... 600 % saturation
Response time (t90):
- 180 seconds
Sensor length:
- 196mm
Connection cable:
- 15m long, with watertight plug (IP65)
Type of protection:
- IP 68 (sensor)
Potentiostatic D.O. sensor with integrated temperature sensor
Design according to the minimum requirements for measuring instruments used at waste water treatment plants defined by ATV (waste water association) in bulletin M256
Potentiostatic D.O. sensor (3-electrode principle)
- To be connected to the EcoLine® or QuadroLine® series measuring transmitters
* With integrated temperature sensor and built-in preamplifier for low impedance, interference-free signal transmission
Equipped with the following features:
- Integrated lightning protection
- Zero current free electrode system
- Exchangeable membrane head with robust 50um special membrane
- Lowest incident flow required
- Double thermistor system for temperature compensation
- OxiCal air calibration without accessories
- Special cable lengths of up to 100m
Measuring range (25°C):
- 0 ... 60mg O2/l
- 0 ... 600 % saturation
Response time (t90):
- 180 seconds
Sensor length:
- 196mm
Connection cable:
- ___ m long, with watertight plug (IP65)
Type of protection:
- IP 68 (sensor)
Accessory kit for D.O. sensors TriOxmatic 600/690/700/700 IQ/700 IN series complete set for regeneration of D.O. electrode Included: 2 exchange membrane heads (WP 600/2) 50 ml electrolyte solution (ELY/A) 50 ml cleaning solution (RL-AG/Oxi) 1x cathode cleaner (SF 300)
Accessory kit for D.O. sensors TriOxmatic 601/701(IQ)/702 (IQ) series complete set for regeneration of D.O. electrode Included: 2 exchange membrane heads (WP 25i/2) 50 ml electrolyte solution (ELY/A) 50 ml cleaning solution (RL-AG/Oxi) 1x cathode cleaner (SF 300)
Exchange membrane heads
Exchange membrane heads (2 pcs)
- For D.O. probes TriOxmatic® 600/690/700 (IQ/IN) series
For TriOxmatic® oxygen sensors of the series 601 and 701