IKA C 2000 Control High Pres Calorimeter 8802400
Enlarge

IKA C 2000 Control High Pres Calorimeter 8802400

PART NO: Y-8802400

The IKA C 2000 control high pressure calorimeter is the newest system from IKA® for determining explosion heat and heat of combustion of solid propellants
A high level of automation with extremely simple handling characterizes this instrument
In addition to the isoperibolic measurement procedure (static jacket), a dynamic (reduced-time) working method is also available
To provide the calorimeter with cooling water, it need to be connected to a thermostat f.e. IKA KV 600 ( accessory) or a firmly installed water connection
The C 2000 basic high pressure is a combination of the C 2000 basic, the decomposition vessel C 62 and the conversion set C 60

- Automatic water handling system includes tempering, filling and emptying of calorimeter inner vessel
- Automatic sample ignition - Validation according to DIN 51900,ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, ASTM E711
- Working methods:
- isoperibol, measurement time: approx. 22 min
- dynamic, measurement time: approx. 7 min
- Compact, integrated modular design for convenient operation
- Cooling water supply via thermostat f.e. IKA KV 600 ( accessory) or firmly installed water connection (C 25 pressure regulating valve recommended)
- Interface connections for each of the following: scale, printer, monitor and sample rack C 5020
- User-friendly software C 5040 CalWin for controlling the calorimeter and administration of measuring data
- Up to eight measuring cells can be controlled by a single PC, using a multi-serial plug- in card PCI 8.2 (accessory)
- LIMS integration is possible
- Special consumables for C 2000 control high pressure:
- C 08 Spool of ignition wire (pure iron) with given gross calorific values and
- C 62.2 Combustion crucibles (stainless steel) for C 62 are included with delivery.
-
Technical Specifications:
- Measuring range max. 40000 J
- Measuring mode adiabatic 22°C no
- Measuring mode isoperibol 22°C no
- Measuring mode dynamic 25°C yes
- Measuring mode isoperibol 25°C yes
- Measuring mode dynamic 30°C yes
- Measuring mode isoperibol 30°C yes
- Measuring mode double dry (ISO 1928) no
- Measuring time dynamic approx. 7 min
- Measuring time isoperibol approx. 22 min
- Reproducibility dynamic (1g benzoic acid NBS39i) 0.1 %RSD
- Reproducibility isoperibol (1g benzoic acid NBS39i) 0.05 %RSD
- Working temperature max. 30°C
- Temperature measurement resolution 0.0001 K
- Cooling medium temperature min. 12°C
- Cooling medium temperature max. 28°C
- Cooling medium permissible operating pressure 1.5 bar
- Cooling medium tap water
- Type of cooling flow
- Flow rate min. 0.3 l/h
- Flow rate max. 70 l/h
- Oxygen operating pressure max. 40 bar
- Interface scale RS232
- Interface printer Centronix
- Interface PC RS232
- Interface test rack yes
- Interface ext. monitor yes
- Interface ext. keyboard yes
- Oxygen filling yes
- Degasification no
- Decomposition detection no
- Decomposition vessel C 5010 no
- Decomposition vessel C 5012 no
- Decomposition vessel C 7010 no
- Decomposition vessel C 7012 no
- Decomposition vessel C 62 yes
- Analysis according to DIN 51900 (1977/84) yes
- Analysis according to ASTM D240 (2002) yes
- Analysis according to ASTM D4809 (2000) yes
- Analysis according to ASTM D1989 (1992) yes
- Analysis according to ASTM D5468 (2002) yes
- Analysis according to ASTM D5865 (2001) yes
- Analysis according to ASTM E711 yes
- Dimensions (W x H x D) 440 x 500 x 450mm
- Weight 30kg
- Permissible ambient temperature 20 - 25°C
- Permissible relative moisture 80 %
- Protection class according to DIN EN 60529 IP 21
- RS 232 interface yes
- Voltage 220 - 240 V
- Frequency 50/60 Hz
- Power input 1800 W

Catalogue Number6.237 467
ManufacturerIKA
Manufacturer P/n8802400