Your basket is empty
BROWSE OUR PRODUCT CATALOGUE

EC analytical columns NUCLEODUR® 100-5 NH2, 5 µm

Pore size 110 Å, particle sizes 3 and 5 µm; 2.5 % C; not endcapped - USP L8

Multi-mode columns (RP and NP):
Normal phase chromatography (NP) with hexan, dichloromethane or 2-propanol as mobile phase for polar compounds such as substituted anilines, esters, chlorinated pesticides
Reversed phase chromatography (RP) of polar compounds like sugars in aqueous-organic eluent systems
Ion exchange chromatography of anions and organic acids using common buffers and organic modifiers
stable against hydrolysis at low pH, working range pH 2-8, 100 % stable in water, suitable for LC-MS

Ideal for:
polar compounds under RP conditions (sugars, DNA bases), hydrocarbons under NP conditions
Eluent in column is n-heptane for the NP mode - RP columns are delivered in acetonitrile - water. For changing the solvent system a rinsing step with THF may be necessary.
Eluent in column n-heptane, particle size 5 µm.

EC analytical columns NUCLEODUR® 100-5 NH2, 5 µm

EC analytical columns NUCLEODUR® 100-5 NH2, 5 µm



Macherey-Nagel MN Nucleodur EC 100-5 NH2 250x4mm 760722.40
PART NO.4AJ-4004536
81119||81891||82132||78947||82304||82792||82288||81337||81348||81362||81027||79329||82078||81302||81734||82995||81657
Type||Shape||Extraction nozzle||Accuracy infra-red||Distance steps||Volume column ml||Resolution air pressure||Ø mm||Weight||Ø heating surface||Max. operating pressure||Film thickness||Particle size µm||Min. immersion depth||Max. temp. resistance °C||Filling quantity mg||PK
||Analytical||Stainless steel||L8|| ||5||n-heptane||250|| ||Fully porous|| ||No||2.5||2 ... 8||60||3.15||1
Macherey-Nagel
760722.40

EC analytical columns NUCLEODUR 100-5 NH2, 5m

0
3
3
1
Price: £447.36
Out of Stock
Macherey-Nagel MN Nucleodur EC 100-5 NH2 150x4.6mm 760721.46
PART NO.4AJ-4004535
81119||81891||82132||78947||82304||82792||82288||81337||81348||81362||81027||79329||82078||81302||81734||82995||81657
Type||Shape||Extraction nozzle||Accuracy infra-red||Distance steps||Volume column ml||Resolution air pressure||Ø mm||Weight||Ø heating surface||Max. operating pressure||Film thickness||Particle size µm||Min. immersion depth||Max. temp. resistance °C||Filling quantity mg||PK
||Analytical||Stainless steel||L8|| ||5||n-heptane||150|| ||Fully porous|| ||No||2.5||2 ... 8||60||2.5||1
Macherey-Nagel
760721.46

EC analytical columns NUCLEODUR 100-5 NH2, 5m

0
3
2
1
Price: £387.84
Out of Stock
Macherey-Nagel MN Nucleodur EC 100-5 NH2 125x4.6mm 760720.46
PART NO.4AJ-4004534
81119||81891||82132||78947||82304||82792||82288||81337||81348||81362||81027||79329||82078||81302||81734||82995||81657
Type||Shape||Extraction nozzle||Accuracy infra-red||Distance steps||Volume column ml||Resolution air pressure||Ø mm||Weight||Ø heating surface||Max. operating pressure||Film thickness||Particle size µm||Min. immersion depth||Max. temp. resistance °C||Filling quantity mg||PK
||Analytical||Stainless steel||L8|| ||5||n-heptane||125|| ||Fully porous|| ||No||2.5||2 ... 8||60||2.06||1
Macherey-Nagel
760720.46

EC analytical columns NUCLEODUR 100-5 NH2, 5m

0
2
1
1
Price: £387.84
Out of Stock
Macherey-Nagel MN Nucleodur EC 100-5 NH2 125x4mm 760720.40
PART NO.4AJ-4004533
81119||81891||82132||78947||82304||82792||82288||81337||81348||81362||81027||79329||82078||81302||81734||82995||81657
Type||Shape||Extraction nozzle||Accuracy infra-red||Distance steps||Volume column ml||Resolution air pressure||Ø mm||Weight||Ø heating surface||Max. operating pressure||Film thickness||Particle size µm||Min. immersion depth||Max. temp. resistance °C||Filling quantity mg||PK
||Analytical||Stainless steel||L8|| ||5||n-heptane||125|| ||Fully porous|| ||No||2.5||2 ... 8||60||1.56||1
Macherey-Nagel
760720.40

EC analytical columns NUCLEODUR 100-5 NH2, 5m

0
3
0
1
Price: £367.68
Out of Stock
Macherey-Nagel MN Nucleodur EC 100-5 NH2 250x4.6mm 760722.46
PART NO.4AJ-4004537
81119||81891||82132||78947||82304||82792||82288||81337||81348||81362||81027||79329||82078||81302||81734||82995||81657
Type||Shape||Extraction nozzle||Accuracy infra-red||Distance steps||Volume column ml||Resolution air pressure||Ø mm||Weight||Ø heating surface||Max. operating pressure||Film thickness||Particle size µm||Min. immersion depth||Max. temp. resistance °C||Filling quantity mg||PK
||Analytical||Stainless steel||L8|| ||5||n-heptane||250|| ||Fully porous|| ||No||2.5||2 ... 8||60||4.150||1
Macherey-Nagel
760722.46

EC analytical columns NUCLEODUR 100-5 NH2, 5m

0
2
4
1
Price: £472.32