EC analytical columns NUCLEODUR® Sphinx RP, 1.8 µm
PART NO.4AJ-4004604
81119||81891||82132||78947||82304||82792||82288||81337||81348||81362||81027||79329||82078||81302||81734||82995||81657
Type||Shape||Extraction nozzle||Accuracy infra-red||Distance steps||Volume column ml||Resolution air pressure||Ø mm||Weight||Ø heating surface||Max. operating pressure||Film thickness||Particle size µm||Min. immersion depth||Max. temp. resistance °C||Filling quantity mg||PK
||Analytical||Stainless steel||L1, L11||Reverse phase||1,8||Acetonitrile/water||50|| ||Fully porous|| ||Yes||15||1 ... 10||60||0.62||1
Macherey-Nagel
760822.40
Analytical columns
NUCLEODUR
0
3
6
1
Price: £681.60
Out of Stock
PART NO.4AJ-4004603
81119||81891||82132||78947||82304||82792||82288||81337||81348||81362||81027||79329||82078||81302||81734||82995||81657
Type||Shape||Extraction nozzle||Accuracy infra-red||Distance steps||Volume column ml||Resolution air pressure||Ø mm||Weight||Ø heating surface||Max. operating pressure||Film thickness||Particle size µm||Min. immersion depth||Max. temp. resistance °C||Filling quantity mg||PK
||Analytical||Stainless steel||L1, L11||Reverse phase||1,8||Acetonitrile/water||50|| ||Fully porous|| ||Yes||15||1 ... 10||60||0.35||1
Macherey-Nagel
760822.30
Analytical columns
NUCLEODUR
0
2
5
1
Price: £681.60
Out of Stock
PART NO.4AJ-4004602
81119||81891||82132||78947||82304||82792||82288||81337||81348||81362||81027||79329||82078||81302||81734||82995||81657
Type||Shape||Extraction nozzle||Accuracy infra-red||Distance steps||Volume column ml||Resolution air pressure||Ø mm||Weight||Ø heating surface||Max. operating pressure||Film thickness||Particle size µm||Min. immersion depth||Max. temp. resistance °C||Filling quantity mg||PK
||Analytical||Stainless steel||L1, L11||Reverse phase||1,8||Acetonitrile/water||50|| ||Fully porous|| ||Yes||15||1 ... 10||60||0.15||1
Macherey-Nagel
760822.20
Analytical columns
NUCLEODUR
0
3
4
1
Price: £681.60
Out of Stock
PART NO.4AJ-4004601
81119||81891||82132||78947||82304||82792||82288||81337||81348||81362||81027||79329||82078||81302||81734||82995||81657
Type||Shape||Extraction nozzle||Accuracy infra-red||Distance steps||Volume column ml||Resolution air pressure||Ø mm||Weight||Ø heating surface||Max. operating pressure||Film thickness||Particle size µm||Min. immersion depth||Max. temp. resistance °C||Filling quantity mg||PK
||Analytical||Stainless steel||L1, L11||Reverse phase||1,8||Acetonitrile/water||30|| ||Fully porous|| ||Yes||15||1 ... 10||60||0.49||1
Macherey-Nagel
760821.46
Analytical columns
NUCLEODUR
0
3
3
1
Price: £739.20
Out of Stock
PART NO.4AJ-4004600
81119||81891||82132||78947||82304||82792||82288||81337||81348||81362||81027||79329||82078||81302||81734||82995||81657
Type||Shape||Extraction nozzle||Accuracy infra-red||Distance steps||Volume column ml||Resolution air pressure||Ø mm||Weight||Ø heating surface||Max. operating pressure||Film thickness||Particle size µm||Min. immersion depth||Max. temp. resistance °C||Filling quantity mg||PK
||Analytical||Stainless steel||L1, L11||Reverse phase||1,8||Acetonitrile/water||30|| ||Fully porous|| ||Yes||15||1 ... 10||60||0.38||1
Macherey-Nagel
760821.40
Analytical columns
NUCLEODUR
0
3
2
1
Price: £681.60
Out of Stock
PART NO.4AJ-4004599
81119||81891||82132||78947||82304||82792||82288||81337||81348||81362||81027||79329||82078||81302||81734||82995||81657
Type||Shape||Extraction nozzle||Accuracy infra-red||Distance steps||Volume column ml||Resolution air pressure||Ø mm||Weight||Ø heating surface||Max. operating pressure||Film thickness||Particle size µm||Min. immersion depth||Max. temp. resistance °C||Filling quantity mg||PK
||Analytical||Stainless steel||L1, L11||Reverse phase||1,8||Acetonitrile/water||30|| ||Fully porous|| ||Yes||15||1 ... 10||60||0.2||1
Macherey-Nagel
760821.30
Analytical columns
NUCLEODUR
0
3
1
1
Price: £681.60
Out of Stock
PART NO.4AJ-4004598
81119||81891||82132||78947||82304||82792||82288||81337||81348||81362||81027||79329||82078||81302||81734||82995||81657
Type||Shape||Extraction nozzle||Accuracy infra-red||Distance steps||Volume column ml||Resolution air pressure||Ø mm||Weight||Ø heating surface||Max. operating pressure||Film thickness||Particle size µm||Min. immersion depth||Max. temp. resistance °C||Filling quantity mg||PK
||Analytical||Stainless steel||L1, L11||Reverse phase||1,8||Acetonitrile/water||30|| ||Fully porous|| ||Yes||15||1 ... 10||60||0.1||1
Macherey-Nagel
760821.20
Analytical columns
NUCLEODUR
0
3
0
1
Price: £681.60
Out of Stock
PART NO.4AJ-4004605
81119||81891||82132||78947||82304||82792||82288||81337||81348||81362||81027||79329||82078||81302||81734||82995||81657
Type||Shape||Extraction nozzle||Accuracy infra-red||Distance steps||Volume column ml||Resolution air pressure||Ø mm||Weight||Ø heating surface||Max. operating pressure||Film thickness||Particle size µm||Min. immersion depth||Max. temp. resistance °C||Filling quantity mg||PK
||Analytical||Stainless steel||L1, L11||Reverse phase||1,8||Acetonitrile/water||50|| ||Fully porous|| ||Yes||15||1 ... 10||60||0.83||1
Macherey-Nagel
760822.46
Analytical columns
NUCLEODUR
0
3
7
1
Price: £739.20